It's been a while.
Any copper wires can be used for EDM. I learned that wire diameter can be decreased by 10-20% by stretching it. So 120 micron wire can ben stretched to drill 100 micron hole.
Happy DACing.
Thursday, October 27, 2011
Wednesday, July 29, 2009
FWHM in CONUSS
Total number of points which can be assigned for the width of EFG in CONUSS is limited. If too many points are assigned for the width, CONUSS crashes but does not specify what is wrong.
Dan Shim learn from Brent Grocholski
Dan Shim learn from Brent Grocholski
Ar loading
In order to prevent blow out, Ar loading should be done before or at least at noon. We don't know why. But we found there is much less chance of blow out in morning loadings. This is particularly true in Summer time when humidity is high.
Tuesday, May 26, 2009
Make Ubuntu+CONUSS faster
Make sure you have the following commands in Ubuntu.bat file.
-----Ubuntu.bat--------------
REM Start qemu on windows.
@ECHO OFF
net start kqemu
qemu -L . -kernel-kqemu -localtime -soundhw all -hda hda.img -m 512
-----Ubuntu.bat--------------
REM Start qemu on windows.
@ECHO OFF
net start kqemu
qemu -L . -kernel-kqemu -localtime -soundhw all -hda hda.img -m 512
Do not load Ar without humidity control
Cryogenic Ar loading should be done at humidity below 40%. Otherwise, sample chamber would expand during or after the loading
Dan Shim
Dan Shim